When you are in search of top-quality Relay Thermal items that are listed with the NSN 5945002749928, we have you covered here on National Stock Number Supply. On this page, you can request a quote on part number GT5045, a Spx Corporation item that is readily available for purchase from our website today! If you would like to procure this particular part or simply wish to receive information for your comparisons, be sure to submit a request with as much information as you can regarding your needs and restrictions. Within 15 minutes of receiving and reviewing a completed form, a member of our staff will reach out to you in order to continue the purchasing process.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items that you require for your operations, we always list everything we offer with as much relevant information as possible. For example, the NSN 5945-00-274-9928 item from Spx Corporation was specifically produced under the CAGE Code 93929. Additionally, with the first digits of its NSN, this item also belongs to the FSC 5945 Relays and Solenoids. With such details, narrowing down your search is made easy. If you have any questions regarding our offerings and services or simply wish to speak with a representative regarding our stock, be sure to give us a call or email at your convenience so that we may assist you however we can!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-274-9928 Item PartTypeName: RELAY,THERMAL | 5945 | 002749928 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M19648/1-106 | E | 2 | 2 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.380 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.650 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
APFR | CONTACT ARRANGEMENT | SINGLE POLE,SINGLE THROW,NORMALLY OPEN |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 32.0 DC |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 2.0 AC OR 1.0 DC |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 6.5 |
CYCV | HEATER POWER RATING IN WATTS | 4.5 |
CYCW | DELAY TIME IN SECONDS | 60.0 ADJUSTABLE OPERATE NOMINAL |
FEAT | SPECIAL FEATURES | MTG HOLES 0.130 INCH DIA SPACED 1.125 INCHES C TO C |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-19648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE HOOK |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-19648/1 GOVERNMENT SPECIFICATION |