When you are in search of top-quality Circuit Breaker items that are listed with the NSN 5925014251840, we have you covered here on National Stock Number Supply. On this page, you can request a quote on part number UPL2-27930-1, a Ai Tek Instruments Llc item that is readily available for purchase from our website today! If you would like to procure this particular part or simply wish to receive information for your comparisons, be sure to submit a request with as much information as you can regarding your needs and restrictions. Within 15 minutes of receiving and reviewing a completed form, a member of our staff will reach out to you in order to continue the purchasing process.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that you only procure the exact items that you require for your operations, we always list everything we offer with as much relevant information as possible. For example, the NSN 5925-01-425-1840 item from Ai Tek Instruments Llc was specifically produced under the CAGE Code 1XP56. Additionally, with the first digits of its NSN, this item also belongs to the FSC 5925 Circuit Breakers. With such details, narrowing down your search is made easy. If you have any questions regarding our offerings and services or simply wish to speak with a representative regarding our stock, be sure to give us a call or email at your convenience so that we may assist you however we can!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-425-1840 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014251840 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
UPL2-27930-1 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRX | Actuator Position Designation | AT EACH POLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP W/DUAL RATING ALL LOCATIONS |
FEAT | Special Features | HANDLE COLOR IS BLACK. |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 DC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
CPRW | Actuator Function | TRIP-RESET |